Power Communication Tech MU81X-IP Specifikace Strana 87

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 110
  • Tabulka s obsahem
  • ŘEŠENÍ PROBLÉMŮ
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 86
KVM over IP Module
5.5.6 Date / Time
Figure 5-28 Date / Time
This link refers to a page, where the internal real-time clock of the IP-KVM can be set up. You
have the possibility to adjust the clock manually, or to use a NTP timeserver. Without a
timeserver, your time setting will not be persistent, so you have to adjust it again, after
IP-KVM loses power for more than a few minutes. To avoid this, you can use a NTP
timeserver, which sets up the internal clock automatically to the current UTC time. Because
NTP server time is always UTC, there is a setting that allows you to set up a static offset to get
your local time.
Warning
There is currently no way to adjust the daylight saving time automatically. So you
have to set up the UTC offset twice a year properly to the local rules of your country.
87 / 110
Zobrazit stránku 86
1 2 ... 82 83 84 85 86 87 88 89 90 91 92 ... 109 110

Komentáře k této Příručce

Žádné komentáře